12 Channels PWHT unit
This page introduce the 12 Channels heat treating UNIT of our products. Temperature category for control, monitor and recording is below than 1100’C.
Hamedsoft PWHT unit
This unit is suitable for all heat treating processes, specially stress relieve, preheat and annealing.
Control unit of this device contain one touch screen HMI (usually 10 inches) that used latest method of Hamedsoft easy program for control, monitor and recording the temperatures and channels.
Output logic for our product is PID and it can control 4 level process or hold in fixed temperature while user switched off.
The accuracy of our products is 0.1 ‘C and time gradient and differential is saving in each 30 seconds. the memory of our products is 40 hours. finally by using flash USB disk drive, one read-only file is decoded in laptop or PC and you can print it or convert it to PDF document.
Our Twelve channels Heat treatment UNIT
Technical Code | Power | Power Supply | Output Voltage | Maximum Elements can connect to a channel | Maximum power for each channel | Output type |
HSP12-85-C | 85 KW | 3P - 380 VAC | 60 VAC | 2 | 7.1 KW | Contactor |
HSP12-85-S | 85 KW | 3P - 380 VAC | 60 VAC | 2 | 7.1 KW | SSR |
HSP12-100-C | 100 KW | 3P - 380 VAC | 65 VAC | 2 | 7.5 KW | Contactor |
HSP12-100-S | 100 KW | 3P - 380 VAC | 65 VAC | 2 | 7.5 KW | SSR |
HSP12-140-C | 140 KW | 3P - 380 VAC | 60 VAC | 4 | 11 KW | Contactor |
HSP12-140-S | 140 KW | 3P - 380 VAC | 60 VAC | 4 | 11 KW | SSR |
HSP12-0220-C | 120 KW | 1P - 220 VAC | 220 VAC | 4 | 10 KW | Contactor |
HSP12-0380-C | 120 KW | 3P - 380 VAC | 220 VAC | 4 | 10 KW | Contactor |
HSP12-0380-C+ | 120 KW | 3P - 380 VAC | 220 VAC or 380 VAC | 4 or 7 | 20 KW | Contactor |
HSP12-0220-V | 120 KW | 1P - 220 VAC | From 0 to 220 VAC | 4 | 10 KW | SCR |
HSP12-0380-V | 120 KW | 3P - 380 VAC | From 0 to 220 VAC | 4 | 10 KW | SCR |
HSP12-0380-V+ | 240 KW | 3P - 380 VAC | From 0 to 380 VAC | 8 | 10 KW | SCR |
How we code our products
HSP | - | A | - | BCD | - | EF | /G |
A | Output channels count | ||||||
1, 3, 6, 12 | |||||||
BCD | Machine power | ||||||
8 | 8 kw, only available for HSP1 | ||||||
16 | 16 kw, only available for HSP1 | ||||||
25 | 25 kw, only available for HSP3 | ||||||
50 | 50 kw, available for HSP3 and HSP6 | ||||||
75 | 75 kw, available for HSP6 and HSP12 | ||||||
100 | 100kw, available for HSP6 and HSP12 | ||||||
150 | 150kw, only available for HSP12 | ||||||
0220 | Available on all products (without transformer) | ||||||
0380 | Available on all products (without transformer) | ||||||
EF | Output kind | ||||||
C | Contactor | ||||||
S | SSR Switches | ||||||
V | SCR, Power regulator, Maximum output voltage is 220V | ||||||
C+ | Contactor, can swap between 220V and 380V | ||||||
V+ | SCR, Power regulator, Maximum output voltage is 380V | ||||||
/G | Additional Input Count | ||||||
Usually input channels are equal with output channels but in some case operators need more input count. This is completely optional but you can add up to 200 TCs for any devices. For example in the 6 channels PWHT machine coded HSP6-100-C/12 have 12 channels input more than its 6 channels input. |
- Our products cataloge
- PWHT UNIT POWER
- PWHT UNIT OUTPUT
- Guarantee and our after sale services